TXDOT WINCORE3.TXT

gINT v. 7 Agency Reports:
  Texas Department of Transportation Drilling Log with data export
  Mimics Texas DOT WINCORE version 3 program.

!!!!!!!!!!!!!!!!!!!!!!
IMPORTANT NOTE:  New Tiles were created to generate the required soil and rock patterns.  You can download and merge the latest tile library from www.gintsoftware.com/support_updates_auxiliary.html.

To double check that you have the required tiles, after the installation (see below), move to Drawings:Drawing Library and print the TXDOT WINCORE3 LITHOLOGY SYMBOLS page and compare to the PDF on the Web site.  If different, you need to download and merge the latest tiles as described above.
!!!!!!!!!!!!!!!!!!!!!!

================
REVISION HISTORY
================
13 March 2005
  Initial Upload
*************************************************

INCLUDED FILES:
TXDOT WINCORE3.GLB
  gINT library file containing:
    Logs             :  TXDOT WINCORE3

    Material Symbols :  TXDOT ANHIDRITE
                        TXDOT BASALT
                        TXDOT CH
                        TXDOT CL
                        TXDOT CONGLOMERATE
                        TXDOT GNEISS
                        TXDOT GRANITE
                        TXDOT GRAVEL
                        TXDOT GYPSUM
                        TXDOT LIGNITE
                        TXDOT LIMESTONE
                        TXDOT MUCK
                        TXDOT NON-STANDARD
                        TXDOT ORGANICS
                        TXDOT PEAT
                        TXDOT REDBED
                        TXDOT SAND
                        TXDOT SANDSTONE
                        TXDOT SCHIST
                        TXDOT SHALE
                        TXDOT SILT
                        TXDOT WATER

    Library Data     :  TXDOT PRIMARY SOIL TYPE

    Lookup Lists     :  TXDOT UNITS

    User System Data :  TXDOT Cone Penetration
                        TXDOT Depth Log Page
                        TXDOT Ft M Factor
                        TXDOT Ft M Format
                        TXDOT Ft M Label
                        TXDOT In Mm Factor
                        TXDOT In Mm Format
                        TXDOT Log Scale Factor
                        TXDOT Log Scale Inc Major
                        TXDOT Log Scale Inc Minor
                        TXDOT Material Graphic
                        TXDOT Units Factor
                        TXDOT Units In NE Out
                        TXDOT Units Input
                        TXDOT Units Output

    Discrete Graphics:  TXDOT LOGO

    Drawing Library  :  TXDOT WINCORE3 LITHOLOGY SYMBOLS

TXDOT WINCORE3.GDT
  gINT project data template.  You will clone this file to create new project files.

TXDOT WINCORE3.GPJ
  gINT project file containing one borehole of example data.  You can use this file to clarify any input procedure questions by looking at the way the data was entered in the Input application.  You can also output this data using the report template to see what the final output looks like.

TXDOT WINCORE3.GCX
  gINT export correspondence file.  This maps from the gINT project structure to the structure required for the File:Import/Export:Export Texas DOT WinCore v. 3 Data command.  This command will then convert to the WinCore v. 3 format.

TXDOT WINCORE3.CSV
  gINT file holding the required WinCore v. 3 data structure.  This file is only needed if you wish to create your own project structure.  It would then be used to build your own correspondence file.  This file would be the "Target" file when building the correspondence file.
*************************************************

INSTALLATION PROCEDURE:
  Copy TXDOT WINCORE3.GDT, .GCX, and .CSV to your gINT data template directory (usually C:\PROGRAM FILES\GINT\DATATMPL or C:\PROGRAM FILES\GINTW\DATATMPL).
  Copy TXDOT WINCORE3.GPJ to your gINT projects directory (usually C:\PROGRAM FILES\GINT\PROJECTS or C:\PROGRAM FILES\GINTW\PROJECTS).
  Merge TXDOT WINCORE3.GLB
    Bring up gINT.
    Move to the Utilities application group and then to the Lib Merge/Copy application.
    Mark "Merge From".
    Specify the source library file as TX_DOT.GLB.  Remember to specify the path or use the launch button (...) to select the file with a file dialog.
    Check the selection and query options to best meet your needs.  If you wish to merge all of the above, mark Select All and Never Query.
    Move all of the tables from the Available Source Table column to the Tables to Merge/Copy column by clicking the >> button.
    Click the Execute button.
*************************************************

SPECIAL NOTES:
1.  The log form is set up to accept data entry in English or Metric units and will output in English or Metric units, depending on the output units specified in the PROJECT table in Input.  The report will perform the necessary conversions for Metric output.  However, unit sensitive data that are embedded within text strings, e.g., "grades stiffer below 5 ft", must be converted manually if output is to be in Metric.  The exceptions to this rule (as per the behavior of the WinCore v. 3 program) are:
  A. Station and offset must be entered in the output units, that is, no conversion is made.
  B. The Confining Pressure and Deviator Stress values must be input in PSI and are always output in PSI, regardless of the Output Units specified.
  C. The Wet Density values must be input in PCF and are always output in PCF, regardless of the Output Units specified.
*************************************************