PRHTA.TXT
gINT v. 5 Agency Reports:
Puerto Rico Highway and Transportation Authority
English Units Input
English Units Output
REVISION HISTORY
================
29 December 2003:
1. Converted to version 5/6 format.
2. Made cosmetic changes in Input to make data entry easier.
3. Made changes to the reports to make maintenance easier.
None of the modifications affected the underlying database or report structures. Files are compatible with previous versions.
----------------------------------
15 March 2001:
Corrected problem with output of bulk sample types on the test pit. They did not print with the last revision.
----------------------------------
02 February 2001:
Added PRHTA mandated sampler symbols
----------------------------------
27 December 2000:
Initial Upload
*************************************************
INCLUDED FILES:
PRHTA.GLB
gINT library file containing:
Logs : PRHTA Log of Boring
PRHTA Log of Test Pit
Log Blocks : PRHTA COMMON
Lookup Lists : PRHTA QU Method
Sampler Symbols : PRHTA AUGER
PRHTA BULK
PRHTA BULK/GRAB
PRHTA CA
PRHTA CORE
PRHTA CORPS
PRHTA DENISON
PRHTA DUTCH CONE
PRHTA NR
PRHTA PISTON
PRHTA SH
PRHTA SPT
User System Data : PRHTA_Depth_Units_Page_1
PRHTA_Blows_Displayed
PRHTA.GDT
gINT project data template. You will clone this file to create new project files.
PRHTA.GPJ
gINT project file containing one borehole and one test pit of example data.
You can use this file to clarify any input procedure questions by looking at the
way the data was entered in the Input application. You can also output this data
using the report template to see what the final output looks like.
*************************************************
INSTALLATION PROCEDURE:
Copy PRHTA.GDT to your gINT data template directory (usually C:\Program Files\GINT\DATATMPL or
C:\Program Files\GINTW\DATATMPL).
Copy PRHTA.GPJ to your gINT projects directory (usually C:\Program Files\GINT\PROJECTS or
C:\Program Files\GINTW\PROJECTS).
Merge PRHTA.GLB
Bring up gINT.
Move to the Utilities application group and then to the Lib Merge/Copy application.
Mark "Merge From".
Specify the source library file as PRHTA.GLB. Remember to specify the path or use
the launch button (...) to select the file with a file dialog.
Check the selection and query options to best meet your needs. If you wish to merge
all of the above, mark Select All and Never Query.
Move all of the tables from the Available Source Table column to the Tables to
Merge/Copy column by clicking the >> button.
Click the Execute button.
*************************************************
SPECIAL NOTES:
1. Remove the "Logo" text and its surrounding rectangle at the upper left, and replace with your company logo (Draw:Discrete Graphics or Draw:Bitmap Symbol).
2. The company information right of the logo is taken from the Help:Company Information dialog.
3. Both log forms are set up to accept data in English units. Output is also in English units. The units under the field names will tell you what units are needed in each units-dependent field.
*************************************************