LOG A GNNN01.TXT
General Purpose gINT version 6 and later Log Reports:
US A size paper (letter)
Predominately geotechnical data presentation
No well
No graph
No legend
English (Imperial) units input and output
Portrait Orientation
REVISION HISTORY
================
23 January 2006:
1. Converted to version 7 format.
2. Made use of column entities.
3. Took advantage of new features that are available since the
initial upload.
16 April 2003:
Converted to version 5 standards.
Took advantage of build associated text capabilities to build header entities.
Added water level discrete graphic to the header entity.
Created User System Data Items for sample data depth, log scale factor, log scale inc major, log scale inc minor.
08 November 1997:
Initial Upload
*************************************************
INCLUDED FILES:
LOG A GNNN01.GLB
gINT library file containing:
Logs : LOG A GNNN01
User System Data Item : LOG A GNNN01 Sample Data Depth
LOG A GNNN01 Log Scale Inc Major
LOG A GNNN01 Log Scale Inc Minor
LOG A GNNN01.GDT
gINT project data template. You will clone this file to create new project files.
LOG A GNNN01.GPJ
gINT project file containing one borehole of example data. You can use this file to clarify any input procedure questions by looking at the way the data was entered in the Input application. You can also output this data using the report template to see what the final output looks like.
*************************************************
INSTALLATION PROCEDURE:
1. Copy LOG A GNNN01.GDT to your gINT data template directory (usually C:\Program Files\GINT\DATATMPL or C:\Program Files\GINTW\DATATMPL).
2. Copy LOG A GNNN01.GPJ to your gINT projects directory (usually C:Program Files\GINTW\PROJECTS or C:Program Files\GINT\PROJECTS ).
3. Merge LOG A GNNN01.GLB:
a) Bring up gINT.
b) Move to the Utilities application group and then to the Lib Merge/Copy application.
c) Mark "Merge From".
d) Specify the source library file as LOG A GNNN01.GLB. Remember to specify the path or use the launch button (...) to select the file with a file dialog.
e) Check the selection and query options to best meet your needs. If you wish to merge all of the above, mark Select All and Never Query.
f) Move all of the tables from the Available Source Table column to the Tables to Merge/Copy column by clicking the >> button.
g) Click the Execute button.
*************************************************
SPECIAL NOTES:
1. You need to remove the "Logo" text at the lower left and its surrounding rectangle. You can then specify your company logo in its place (Draw:Discrete Graphics).
2. The company information at the at the lower left is taken from the Help:Company Information dialog.
*************************************************