GTB A ENNL01.TXT
General Purpose gINT v. 5 Reports:
graphical Table (actually 2 plus a graph) (gINT Professional License required; these will not run with gINT Logs or logWRITER+)
A (8.5x11") size paper
Primarily Environmental report
No Well
No Graph
with Legend
English (Imperial) units
Portrait Orientation
Well Development Record report (graphical table)
Well Purge Record report (graphical table)
Hydrograph report (graph)
**************************************
Note there are calculations made on these reports for values such as well volume, water column height, and saturated filter pack thickness. As with all our work, every effort has been made to ensure that these calculations are correct. However, gINT Software assumes no liability for any errors in these calculations or in the use of these reports. The user assumes any liability and must verify that output from reports is accurate.
**************************************
Revision History:
16 April 2003:
Updated to version 5 standards.
Changed file to new naming convention GTB A ENNL01, formerly GTB A ENNL01.
Removed all underscores in Table and Field names as well as User System Data items.
07 November 2000:
From the table WELL DEVELOPMENT DETAILS, removed the Boolean (True/False) fields Hand_Pump, Submersible Pump, Bailer, and Other.
In the GTB A ENNL01 WELL DEVELOPMENT graphical table changed the output conditions on the "X"s right of Hand Pump, Submersible Pump, Bailer, and Other to expressions that search the Method field in the WELL DEVELOPMENT DATA table and mark those items appropriately. This eliminated the need for the Boolean fields in the WELL DEVELOPMENT DETAILS table.
30 October 2000:
Initial Upload
*************************************************
INCLUDED FILES:
GTB A ENNL01.GLB
gINT library file containing:
Graphs : GTB A ENNL01 HYDROGRAPH
Graphical Tables : GTB A ENNL01 WELL DEVELOPMENT
Graphical Tables : GTB A ENNL01 WELL PURGE
Graphical Table Blocks : GTB A ENNL01 COMMON
Drawing Library Block : GTB A ENNL01 COMPANY INFORMATION
Lookup Lists:
GTB A ENNL01 ABBREVIATIONS
GTB A ENNL01 CONDUCTIVITY Conductivity units
GTB A ENNL01 DEVELOPMENT METHOD Well development methods.
GTB A ENNL01 PURGE EVENT
GTB A ENNL01 TEMP UNITS F or C - units of temperature choices
User System Data items:
GTB A ENNL01 Casing Radius ID calculation of casing radius ID
GTB A ENNL01 Casing Radius OD calculation of casing radius OD
GTB A ENNL01 Casing Volume WD casing volume for well development record
GTB A ENNL01 FiltPackPor Vol filter pack pore volume calculation
GTB A ENNL01 Hole Radius calculation of hole diameter
GTB A ENNL01 Saturated Filter Pack saturated filter pack thickness determination for well development record
GTB A ENNL01 Stickup well casing stickup calculation
GTB A ENNL01 Water Column WD height of water column in well for well development record
GTB A ENNL01 Water Column WP height of water column in well for well purge record
GTB A ENNL01 WL Depth Corrected WD water level depth corrected for stickup used on well development record
GTB A ENNL01 WL Depth Corrected WP water level depth corrected for stickup used on well purge record
GTB A ENNL01 WL Depth WellPurge extracts water level depth for well purge record
GTB A ENNL01.GDT
gINT project data template. You will clone this file to create new project files.
GTB A ENNL01.GPJ
gINT project file containing three boreholes of example data, each with multiple development and purge events. You can use this file to clarify any input procedure questions by looking at the way the data was entered in the Input application. You can also output this data using the report template to see what the final output looks like.
*************************************************
INSTALLATION PROCEDURE:
Copy GTB A ENNL01.GPJ to your gINT projects directory (usually C:\GINT\PROJECTS or C:\Program Files\GINT\PROJECTS).
Merge GTB A ENNL01.GLB:
Bring up gINT.
Move to the Utilities application group and then to the Lib Merge/Copy application.
Mark "Merge From".
Specify the source library file as GTB A ENNL01.GLB. Remember to specify the path or use the launch button (...) to select
the file with a file dialog.
Check the selection and query options to best meet your needs. If you wish to merge all of the above, mark Select All
and Never Query.
Move all of the tables from the Available Source Table column to the Tables to Merge/Copy column by clicking the >> button.
Click the Execute button.
*************************************************
SPECIAL NOTES:
1. Remove the "Logo" text and its surrounding rectangle and replace with your company logo (Draw:Discrete Graphics or Draw:Bitmap Symbol).
2. The company information is taken from the Help:Company Information dialog.
3. You can easily change these reports to work with A4 paper. Just modify the Left Margin, Bottom Margin and Paper Size properties on the Report Properties dialog for each report. You won't have to change the units from inches to millimeters, it will work this way just fine.
*************************************************