FNC AB GWGN02.TXT

General Purpose gINT version 5 Fence Report:
  A size paper (letter - 216 x 279 mm)
  B size paper (tabloid - 279 x 432 mm)

  Predominately geotechnical data presentation
  With well column
  With graph
  No legend

  Landscape orientation
  Metric input and output
*************************************************

================
REVISION HISTORY
================

03 December 2002

  1. Increased the Left Margin to 1.0 for the B-size report.
  2. Created a User System Data item for the Sample Depth for the N Value Plot vs Depth and WC and DD Text with Depth entities.
  3. Renamed files to FNC AB GWGN02(formerly fagwgn02).
  4. Created B-size report and added it to the library
  5. Converted to version 5 format.
  6. Made the N Value, WC, and DD columns variable, that is, they are suppressed if there are no data for a borehole.
*************************************************

23 May 1998:  Initial Upload
*************************************************

INCLUDED FILES:
FNC AB GWGN02.GLB
  gINT library file containing:
    Fences:  FNC AB GWGN02 - A Size
             FNC AB GWGN02 - B Size

    Lookup Lists: FNC AB GWGN02 UNITS

    User System Data: FNC AB GWGN02 Sample Depth Midpoint


FNC AB GWGN02.GDT
  gINT project data template.  You will clone this file to create new project files.

FNC AB GWGN02.GPJ
  gINT project file containing four boreholes of example data.  You can use this file to clarify any input procedure questions by looking at the way the data was entered in the Input application.  You can also output this data using the report template to see what the final output looks like.
*************************************************

INSTALLATION PROCEDURE:
  Copy FNC AB GWGN02.GDT to your gINT data template directory (usually C:\PROGRAM FILES\GINTW\DATATMPL or C:\PROGRAM FILES\GINT\DATATMPL).
  Copy FNC AB GWGN02.GPJ to your gINT projects directory (usually C:\PROGRAM FILES\GINTW\PROJECTS or C:\PROGRAM FILES\GINT\PROJECTS).
  Merge FNC AB GWGN02.GLB:
    Bring up gINT.
    Move to the Utilities application group and then to the Lib Merge/Copy application.
    Mark "Merge From".
    Specify the source library file as FNC AB GWGN01.GLB.  Remember to specify the path or use the launch button (...) to select the file with a file dialog.
    Mark Select All and Never Query.  There is only one record to merge.
    Move all of the tables from the Available Source Table column to the Tables to Merge/Copy column by clicking the >> button.
    Click the Execute button.
*************************************************

SPECIAL NOTES:
1.  This report has more than you will probably want on a fence.  However, it is easier to remove than to add, so delete what you don't want.

2.  The Table/Field names may be different in the report than your project databases.  In this case some of the data will not print when using this form with your databases.  To correct this, move to Data Design:Project Database.  Open the FNC AB GWGN02.GPJ file (File:Open Project).  Move through the different tables and change the table names/fields names appropriately to match your project databases.  On save each table the field replace dialog will appear.  In the "Reports to Scan" field select Fence!FNC AB GWGN02.  This will change the table/field names in the fence report to match your project databases.
*************************************************