FNC AB GWGN01.TXT
General Purpose gINT version 5 Fence Report:
US A size paper (letter - 8.5 x 11)
US B size paper (tabloid - 11 x 17)
Page units in inches
Predominately geotechnical data presentation
With well column
With graph (SPT N Value)
No legend
Landscape Orientation
English (Imperial) units input and output
Metric units input and output
*************************************************
================
REVISION HISTORY
================
03 December 2002
1. Increased the Left Margin to 1.0 for the B-size report.
2. Created a User System Data item for the Sample Depth for the N Value Plot vs Depth and WC and DD Text with Depth entities.
3. Corrected the Dry Density Text with Depth entity to work with English (Imperial)/Metric units.
*************************************************
20 October 2002
1. Renamed files to FNC AB GWGN01 (was fagwgn01).
2. Converted reports to English (Imperial)/Metric input and output.
3. Created B-size report and added it to the library
*************************************************
11 May 2002:
1. Converted to version 5 format.
2. Made the N Value, WC, and DD columns variable, that is, they are suppressed if there are no data for a borehole.
*************************************************
03 September 1997:
Initial Upload
*************************************************
INCLUDED FILES:
FNC AB GWGN01.GLB
gINT library file containing:
Fences: FNC AB GWGN01 - A Size
FNC AB GWGN01 - B Size
Lookup Lists: FNC AB GWGN01 UNITS
User System Data: FNC AB GWGN01 Ft M Factor
FNC AB GWGN01 Ft M Format
FNC AB GWGN01 Ft M Label
FNC AB GWGN01 Ft M Label Long
FNC AB GWGN01 Units Factor
FNC AB GWGN01 Units In NE Out
FNC AB GWGN01 Units Input
FNC AB GWGN01 Units Output
FNC AB GWGN01 Density Conv
FNC AB GWGN01 Density Factor
FNC AB GWGN01 Density Format
FNC AB GWGN01 Density Label
FNC AB GWGN01 Sample Depth Midpoint
FNC AB GWGN01.GDT
gINT project data template. You will clone this file to create new project files.
FNC AB GWGN01.GPJ
gINT project file containing four boreholes of example data. You can use this file to clarify any input procedure questions by looking at the way the data was entered in the Input application. You can also output this data using the report template to see what the final output looks like.
*************************************************
INSTALLATION PROCEDURE:
Copy FNC AB GWGN01.GDT to your gINT data template directory (usually C:\PROGRAM FILES\GINTW\DATATMPL or C:\PROGRAM FILES\GINT\DATATMPL).
Copy FNC AB GWGN01.GPJ to your gINT projects directory (usually C:\PROGRAM FILES\GINTW\PROJECTS or C:\PROGRAM FILES\GINT\PROJECTS).
Merge FNC AB GWGN01.GLB:
Bring up gINT.
Move to the Utilities application group and then to the Lib Merge/Copy application.
Mark "Merge From".
Specify the source library file as FNC AB GWGN01.GLB. Remember to specify the path or use the launch button (...) to select the file with a file dialog.
Mark Select All and Never Query. There is only one record to merge.
Move all of the tables from the Available Source Table column to the Tables to Merge/Copy column by clicking the >> button.
Click the Execute button.
*************************************************
SPECIAL NOTES:
1. With gINT, each report stores the printer to which it will output. We have set up these forms to work with our printer. When you use these forms for the first time, if the assigned printer does not exist on your system, the program automatically substitutes your default Windows printer. If you wish the B-Size form to output to your default printer, and the printer is capable of 11x17" (also called Tabloid or "B" size) paper, everything will work fine. If not, you must change the printer associated with the form. To do so:
· In gINT move to the Reports application group.
· Move to the Fences report tab.
· Select the File:Print:Printer Setup menu item
· Change the Printer appropriately.
· Select the File:Page:Properties menu item and make sure the paper size property is set to 11x17, Tabloid, or B (it can vary between printers).
Changing the printer in Reports stores the setting. You can also change the printer at output time using the same steps but, like all changes at output time, the setting will only be in effect while that report is current and will revert to the value set in Reports.
2. This report has more than you will probably want on a fence. However, it is easier to remove than to add, so delete what you don't want.
3. The Table/Field names may be different in the report than your project databases. In this case some of the data will not print when using this form with your databases. To correct this, move to Data Design:Project Database. Open the FNC AB GWGN01.GPJ file (File:Open Project). Move through the different tables and change the table names/fields names appropriately to match your project databases. On save each table the field replace dialog will appear. In the "Reports to Scan" field select Fence!FNC AB GWGN01. This will change the table/field names in the fence report to match your project databases.
*************************************************