FNC 43 GWGN01.TXT
General Purpose gINT version 5 Fence Report:
A4 size paper (210 x 297 mm)
A3 size paper (297 x 420 mm)
Predominately geotechnical data presentation
With well column
With graph
No legend
Landscape orientation
Metric input and output
================
REVISION HISTORY
================
03 December 2002
1. Increased the Left Margin to 1.0 for the B-size report.
2. Created a User System Data item for the Sample Depth for the N Value Plot vs Depth and WC and DD Text with Depth entities.
3. Renamed files to FNC 43 GWGN01.
4. Created B-size report and added it to the library
5. Converted to version 5 format.
6. Made the N Value, WC, and DD columns variable, that is, they are suppressed if there are no data for a borehole.
*************************************************
03 September 1997
Initial upload
*************************************************
INCLUDED FILES:
FNC 43 GWGN01.GLB
gINT library file containing:
Fences: FNC 43 GWGN01 - A4 Size
FNC 43 GWGN01 - A3 Size
Lookup Lists: FNC 43 GWGN01 UNITS
User System Data: FNC 43 GWGN01 Sample Depth Midpoint
FNC 43 GWGN01.GDT
gINT project data template. You will clone this file to create new project files.
FNC 43 GWGN01.GPJ
gINT project file containing four boreholes of example data. You can use this file to clarify any input procedure questions by looking at the way the data was entered in the Input application. You can also output this data using the report template to see what the final output looks like.
*************************************************
INSTALLATION PROCEDURE:
Copy FNC 43 GWGN01.GDT to your gINT data template directory (usually C:\PROGRAM FILES\GINTW\DATATMPL or C:\PROGRAM FILES\GINT\DATATMPL).
Copy FNC 43 GWGN01.GPJ to your gINT projects directory (usually C:\PROGRAM FILES\GINTW\PROJECTS or C:\PROGRAM FILES\GINT\PROJECTS).
Merge FNC 43 GWGN01.GLB:
Bring up gINT.
Move to the Utilities application group and then to the Lib Merge/Copy application.
Mark "Merge From".
Specify the source library file as FNC AB GWGN01.GLB. Remember to specify the path or use the launch button (...) to select the file with a file dialog.
Mark Select All and Never Query. There is only one record to merge.
Move all of the tables from the Available Source Table column to the Tables to Merge/Copy column by clicking the >> button.
Click the Execute button.
*************************************************
SPECIAL NOTES:
1. This report has more than you will probably want on a fence. However, it is easier to remove than to add, so delete what you don't want.
2. The Table/Field names may be different in the report than your project databases. In this case some of the data will not print when using this form with your databases. To correct this, move to Data Design:Project Database. Open the FNC 43 GWGN01.GPJ file (File:Open Project). Move through the different tables and change the table names/fields names appropriately to match your project databases. On save each table the field replace dialog will appear. In the "Reports to Scan" field select Fence!FNC 43 GWGN01. This will change the table/field names in the fence report to match your project databases.
*************************************************